n
Features
²
Widely applied to the starting and running of AC single-phase motors at 50Hz/60Hz frequency power.
²
Self-healing property
²
Good stability and reliability
²
Safer with Explosion-proofed design
²
Round capacitor, can be provided oval capacitor
Single capacitor, can be provided double capacitor.
Specifications
Reference standards
|
GB/T 3667.1( IEC60252-1)
|
Climatic category
|
40 / 70 / 21、40 / 85 / 21
|
Class of operation
|
Class B (10000h) Class C (3000h)
|
Class of safety protection
|
S0/S2
|
Voltage range
|
250VAC、370VAC、440VAC、450VAC
|
Capacitance range
|
2~100μF
|
Capacitance tolerance
|
± 5% 、 ± 10%、± 15%
|
Dissipation factor
|
20 x10-4 (100Hz,20°C)
|
Test voltage terminal to terminal UTT
|
2 Un for 2 seconds
|
Test voltage terminal to case UTC
|
(2Un+1000)VAC or 2000VAC- 50Hz for 60 seconds
|
Insulation Resistance
|
≥3000s (100Hz,20°C,1min)
|